Wiring A Bathroom Fan / Light With 2 Switches

Hello -



I'm attempting to install a new bathroom vent fan / light combo.  I pulled out the old one from the ceiling and am ready to install the new one.  I'm not sure how to wire up the new one.



The wire coming from the 2 Switches/Wall has the following 4 wires:  Black, White, Red, Bare Copper Ground



The wires coming from the Light/Fan Unit a

Light:  Black, White, Red

Fan:  Black, White

Fan/Light Housing:  Green Ground Wire



Any help would be appreciated.



Thanks!
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

I am trying to install a SunSmart Digital Timer to my hall lightswitch (single pole). The timer has 5 wires: Black, White, Blue, Red, and Green. My switch box only has 3 wires: Black, White, and the bare ground wire. I connected the black to the black, white to white, and green to the bare ground. I have power to the timer but the light doesn't work. What should I do with the blue and red wires? Right now I have each capped off. Thanks.
      
Hello I need seriouse help! In my situation I have a three switch, one for the light, one for the vent fan, and one for the heater. This is in a bathroom rent house. My problem is that when I turn the switch on for the light, the light and fan turn on, when I switch the heater on, that switch does nothing, the same when I switch the fan on. The wall plate is labeled: light, fan, heater. So what I attempted to do is put a switch outlet combo in. I have two black wires, two white wires and a ground. So I put the black wires on brass and the white wires on black,( they are black screws instead of silver, not sure if I got the right kind of switch). So when I did that, when I turn the switch on, the fan turns on, but no light, also when the switch is on the outlet is hot.( which fine that is how I want it). But what did I do wrong, why does fan work but not the light. I my biggest fear is that I might have made a fire hazard. Please help and tell me if what have done is safe, and maybe help me figure out how to turn the fan and light on with the same switch..  Thank you for all your input, have trouble falling asleep, keep thinking the house might burn down.. Sorry for the long post
      
Hi, I recently moved into a 1954 house with a  20amp electrical system, not the old fuse type, but there are no ground wires.



I removed an old light and replaced it with a light fan combo. As I removed the old light (after turning off the breaker) I noticed from the ceiling that there were 2 white wires tied together with a wire nut and 2 black wires, one attached to the white wire in the light and the other attached to the black one from the light. Feeling this was wrong and should be black to black, white to white, (even knowing full well the light was working fine before I disconnected it) I wired the fan the way I've always wired fan lights,  white to white, blue and black to black.  (again, knowing full well the light was working the other way). Turned breaker on then powered on switch. POP at the switch, breaker switched off. I reworked it back to the way it was before with whites tied off, black to white, black and blue to black, turned it back on and  viola, things worked fine. (I know, duh... Right???)

2 questions from this experience...

1. Why would the 2 whites be tied off with only black wires used?

And 2. It seems that one of the light switches in the same circuit as the blown one is now working soft. In other words, it used to make the normal click noise when turned on/off but now it just moves softly up and down without the click. Could I have damaged something when I mis-wired?
      
Hello all, and thank you in advance for any help you can provide! Here is the deal I wanted to put a bathroom exhaust fan in and was told I could come off the existing switch to cut the wire, install a junction box, tie the wires all back in adding the wires for the fan. Trouble is the bathroom light stays on with the switch off. Turn the switch on light dims and the fan now runs, switch off fan shuts off light goes bright used black to black white to white where oh where did I go wrong!?
      
I have an outdoor light fixture that I am trying to replace.  The house was built ten years ago.



When I removed the original lamp, I noticed one of the two leads was wired to the ground, and one was wired to the black wire, which is hot per my current sensor.  There are three wires in the box - black, ground (bare copper), and white or neutral, all from a single romex cable.  Unfortunately, I do not recall where the white was when I removed the original. 



I wired the new lamp per the instructions, something I have done many times before - black to black, white to white, and bare copper ground to ground.  Nothing.  The lamp and bulbs are brand new, and I have tried four separate bulbs.  I checked the black and neutral with my current sensor and with the switch on and the lamp installed this way, both show as hot. With the lamp not installed, the switch on, and the wires disconnected only the black shows as hot.  The switch is single pole, and appears to be wired correctly with a black to each screw on one side and a copper ground on the other.



Assuming the new fixture was bad, I reinstalled the old fixture correctly -  black to black, white to white, and bare copper ground to ground.  Still nothing. No light, and I confirmed the bulb is good by putting it in another lamp.   The only way to get it to light is to connect the neutral in the lamp to the bare copper ground.



I capped the wires, turned the circuit back on, and identified all the outlets, switches and fixtures on the same circuit.  I opened every one of them up (four lights and eight outlets) and found three (one switch and two fixtures in another room) where multiple commons connect.  All were properly connected.  My outlet tester shows all outlets as "correct".  I found no instances of grounds connected to commons or vice-versa.



Any ideas?  Is it proper to wire this thing the way I found it?



Thanks for any and all advice!
      
Hello,



I am replacing a bath light and I am a bit confused by the wiring. I can reattach the wires with the new fixture exactly like the old fixuture was attached but the old fixture did not have a ground connection.



Here is how the wires a



Two whites connected to each other but not to the fixture.

One white and one bare copper wire (I thought it was the ground) connected together and to the white wire of the ligh fixture

one black wire connected to the black wire of the light fixture



How to I connect the the fixture green wire in this configuration?



Thanks
      
Hello!



In a house I recently bought I have a strange situation.



There is a three way switch on one side of the wall with two sets of wires coming in:



Red, Black, White

Black, White



and then one stray Black that goes to the duplex receptacle on the other side of the wall (on the OUTSIDE of the wall!  Clearly an afterthought.)



Into the receptacle goes this strange black single wire from the light switch and the usual black and white wires + ground wire.



I went to change the ugly receptacle to a decora and now it doesn't work, though I'm not 100% sure it worked before.



I've wired the new receptacle as I remember it being wired before, any idea what is wrong? 



I've attached a diagram!



Thanks in advance for any input.
      
Older house with the metal enclosed wiring has stumped me.  I am attempting to add a second switch for a fan off existing light switch in bathroom.  Existing wiring:  W,B,R from panel, W,B to light.  2 white wire are tied together, two black wires to one contact and red to other contact on switch.  Disconnected all wires and confirmed the black is live from panel.  It seems to me the light is seeing power the entire time since the blacks are connected? I'm confused, please help. how do I add another switch onto this circuit?  Thanks!
      
I am replacing the fan in one of our guest bedrooms and thought it would also be a good time to replace the switch.  Currently there is one switch to turn the fan and light on/off. 



I'd like to put the fan and light on two separate switches.  It appears that 12/3 or 14/3 is already in place (white, black and red/pink wires in switch enclosure w/ bare copper for ground).  I'd also like to make the light dimmable and the fan speed adjustable from these switches.  Could anyone recommend a good switch(es) to accomplish this?
      
How to install a ceiling fan light when the power 14/2 goes to the fan/light then to the fan/light control (blue, black, black/white, green)?