Please Help Me Understand Something

I am trying to understand how to wire a certain situation.  I have found how to wire 1 light coming from the service line and into the switch (white connected to light, black spliced into switch with white returning to light marked as hot) but I would have 2 lights before the switch.  How do you wire that appropriately?
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

Greetings all.



This is my first post here, I hope it goes well.



My name is Joe and I have searched Google. and this forum for my answer but have not been able to find a definitive answer to my question.  I have seen many replies talking about getting a tone generator or a line tracer but my experience is that tone generators are for Data and phone cables rather than electrical cables and the line tracers I've found online all seem to be about tracing the line back to the breaker panel so without knowing more I'm hesitant to purchase a line tracer in case it cannot do what I want.

My dilemma is very likely very simple to anyone with electrical experience so I hope it's not too trivial for this crowd.

I have recently purchased a house that is over 120 years old and have a motion sensor light on the porch that is supposedly connected to a switch inside but does not turn on.  I've opened the wall plate and used a voltage indicating pen to see where the electricity is.  In this case there are two light switches, one that has lines that have been spliced and another that supposedly leads to the porch light according to a long time tenant in that unit.  It all looks like a bit of a mess and the connections don't make sense.  In this scenario the black cables have the electricity and the white cables complete the circuit.  The switch to the porch light has a black cable coming from the top of the box going to the switch and a white cable connected to the other screw that comes from splitting the white cable from the other switch.  What I would like to do is know which cables in that wall box correspond to the cables to the porch light.  Can anyone give me an idea what I should do?

Do I need something like the Amprobe advanced wire tracer (http://www.professionalequipment.com...0/wire-tracer/) and can it do what I need, or is there something simpler I can do?

All help is appreciated.

Thanks



Joe
      
Hello I need seriouse help! In my situation I have a three switch, one for the light, one for the vent fan, and one for the heater. This is in a bathroom rent house. My problem is that when I turn the switch on for the light, the light and fan turn on, when I switch the heater on, that switch does nothing, the same when I switch the fan on. The wall plate is labeled: light, fan, heater. So what I attempted to do is put a switch outlet combo in. I have two black wires, two white wires and a ground. So I put the black wires on brass and the white wires on black,( they are black screws instead of silver, not sure if I got the right kind of switch). So when I did that, when I turn the switch on, the fan turns on, but no light, also when the switch is on the outlet is hot.( which fine that is how I want it). But what did I do wrong, why does fan work but not the light. I my biggest fear is that I might have made a fire hazard. Please help and tell me if what have done is safe, and maybe help me figure out how to turn the fan and light on with the same switch..  Thank you for all your input, have trouble falling asleep, keep thinking the house might burn down.. Sorry for the long post
      
Hello!



In a house I recently bought I have a strange situation.



There is a three way switch on one side of the wall with two sets of wires coming in:



Red, Black, White

Black, White



and then one stray Black that goes to the duplex receptacle on the other side of the wall (on the OUTSIDE of the wall!  Clearly an afterthought.)



Into the receptacle goes this strange black single wire from the light switch and the usual black and white wires + ground wire.



I went to change the ugly receptacle to a decora and now it doesn't work, though I'm not 100% sure it worked before.



I've wired the new receptacle as I remember it being wired before, any idea what is wrong? 



I've attached a diagram!



Thanks in advance for any input.
      
Greetings!

I'm hoping for some help, I bought a house recently where the laundry room light switch does not work. I found this in the ceiling box:



Two black wires capped off

One white wire capped off

Three white wires going to the fixture

Two black wires going to the fixture



I replaces the switch to rule that out and it still doesn't work.



There is one black and one white wire going to the switch.



Any ideas on how to wire it properly?



Thanks!
      
We had a pipe disconnect above the downstairs bathroom and the ceiling just about came down, so I decided since it was a hedious looking space, that it was a sign from the gods: Reno time!



Im now at the wiring stage. Originally there was a junction box with a light fixture out one side and a single pole switch(no ground screw...grnd wire attached to the box)on  the other. Typical set up: white from switch marked "hot" or "black" at both ends, and spliced with the incoming power's black wire. Then remaining blacks are spliced together as are the remaining whites... grounded accordingly.



What Im trying to do now is add a GFCI receptical to the mix. But Im having some trouble figuring it all out. NOTE: light fixture is not installed yet, just the wire for it with the ends capped off with a wire nut on each of the wires (Wht/Black/Grnd)



First, whats in the walls: Circuits on a 15 AMP fuse with older (but not the oldest) 12/2 wire with a blue weaved fiber outside cover. Still looks to be in great shape. I've continued using newer, yellow (Lomex or Romex?) 12/2 from homedepot as I've read that you should not mix 14 and 12 together.

All that is on the cicuit is 3 pot lights with 65w bulbs, single bulb on the stairway and what ever goes in the bathroom, so from my math, there should be plenty of room left on the circuit.



What I've tried so far:

A: I spliced the "hot"/"black" white wire from the switch to the incoming power's black, like before. Then I spliced all remaining blacks together with a wire nut, then the same with all remaining whites and then all grounds (did not attach any grnd wire to the Junction box).



Result, Nothing. After switching on the power, I tested the GFCI with a voltage tester as well as the switch and got no read.



B: Undid everything, re-spliced all like to like: all blck together, all white together..etc.



Result: Fuse trips.



Im no electrician, which I imagine is blatantly obvious from the above post, but I am following a Homedepot wiring manual, its just that what Im trying to do is not really addressed in the book... at least not directly. So I've been trying to figure it out by reading every single page, but Im still at a loss.



I've attached a very basic diagram of what is there right now. Any advice would be most appreciated.

Thanks in advance,

John
      
I have an outdoor light fixture that I am trying to replace.  The house was built ten years ago.



When I removed the original lamp, I noticed one of the two leads was wired to the ground, and one was wired to the black wire, which is hot per my current sensor.  There are three wires in the box - black, ground (bare copper), and white or neutral, all from a single romex cable.  Unfortunately, I do not recall where the white was when I removed the original. 



I wired the new lamp per the instructions, something I have done many times before - black to black, white to white, and bare copper ground to ground.  Nothing.  The lamp and bulbs are brand new, and I have tried four separate bulbs.  I checked the black and neutral with my current sensor and with the switch on and the lamp installed this way, both show as hot. With the lamp not installed, the switch on, and the wires disconnected only the black shows as hot.  The switch is single pole, and appears to be wired correctly with a black to each screw on one side and a copper ground on the other.



Assuming the new fixture was bad, I reinstalled the old fixture correctly -  black to black, white to white, and bare copper ground to ground.  Still nothing. No light, and I confirmed the bulb is good by putting it in another lamp.   The only way to get it to light is to connect the neutral in the lamp to the bare copper ground.



I capped the wires, turned the circuit back on, and identified all the outlets, switches and fixtures on the same circuit.  I opened every one of them up (four lights and eight outlets) and found three (one switch and two fixtures in another room) where multiple commons connect.  All were properly connected.  My outlet tester shows all outlets as "correct".  I found no instances of grounds connected to commons or vice-versa.



Any ideas?  Is it proper to wire this thing the way I found it?



Thanks for any and all advice!
      
I have two 3-way switches in my master bath that have never worked properly. The house is very old and has been worked on over the years by many different people with greatly varying levels of skill. I was finally fed up with these switches and tried to fix them. I tried to follow instructions I found online, so with the power off I disconnected all the wires from both switches, then turned the power back on and used my volt-meter to discover which wire was hot. It turned out to the a red wire at switch #1. The other two wires are white and black (and yes, there also is a ground). I connected this hot wire to the darkest screw, connected the white and black to the other two screws and tried to test for continuity at the other switch. I couldn't get a reading on any of the wires at the other end. I tried turning the power back on and testing to see which wire was now hot at the second switch. It was the white wire, so I attached that to the darkest terminal, and attached the red and black to the other two terminals. The switches don't work any better than they did before I started - that is, both switches have to be turned on for the light to come on. What is my problem here? Thank you!
      
Hello. I'm a new home owner and DIY-er. I have 3 fluorescent lights  in my basement. I just replaced the fixtures' older ballasts with new  T8 ballasts in the first two lights and they work fine. I am having  trouble with the third light's wiring to the ceiling. I cut and removed  the old ballast without paying much attention because I was able to wire  the first two lights without any problem. I connected the new ballast  to the bulb sockets in the fixture, just like I did with the first two  lights. When I went to connect the ballast's black and white power lines  to the ceiling lines, I was thrown off by a red wire, which I guess is  connected to the light switch.  In addition, this light is connected to  the one of the other fluorescent lights and both are controlled by the  switch. I have attached  pictures of how I have it wired.



The way I have it wired now,  the other light turns on and works fine when the switch is flipped.  However, this light has the bulb flicker and then not turn on. If anyone  can tell what I'm doing wrong from looking at the pictures, I'd  appreciate any help! Thanks!
      
Hi, I have a fluorescent light I'd like to remove and add a tracklight.



Luckily it's in the basement with an unfinished ceiling.



here's the circuit map as is now:



1. breaker to fluorescent light.... connections inside

2. fluorescent light to switch at the top of the stairs

3. switch to the light in the stairwell. This terminates the circuit.



The wiring is all 14/2



I'd like to replace the the fluorescent light with a track light, but I'm not sure how to continue the circuit to the switch in the stairwell.



Is it safe to...



1. bring the cable from the breaker to the junction box.

2. connect the black wire with the black wire on the light AND the black wire leaving the box to the switch in the stairwell using a marette.

3. connect the white wire with the white wire on the light AND the white wire leaving the box to the switch in the stairwell using a marette

4. connecting a 6 inch bare 14 gauge wire to the box ground screw, then using a marette, connecting it with the ground wire from the cable entering the box as well as the one leaving and also the ground wire from the light.



Will this work and is it safe?
      
Hi, I recently moved into a 1954 house with a  20amp electrical system, not the old fuse type, but there are no ground wires.



I removed an old light and replaced it with a light fan combo. As I removed the old light (after turning off the breaker) I noticed from the ceiling that there were 2 white wires tied together with a wire nut and 2 black wires, one attached to the white wire in the light and the other attached to the black one from the light. Feeling this was wrong and should be black to black, white to white, (even knowing full well the light was working fine before I disconnected it) I wired the fan the way I've always wired fan lights,  white to white, blue and black to black.  (again, knowing full well the light was working the other way). Turned breaker on then powered on switch. POP at the switch, breaker switched off. I reworked it back to the way it was before with whites tied off, black to white, black and blue to black, turned it back on and  viola, things worked fine. (I know, duh... Right???)

2 questions from this experience...

1. Why would the 2 whites be tied off with only black wires used?

And 2. It seems that one of the light switches in the same circuit as the blown one is now working soft. In other words, it used to make the normal click noise when turned on/off but now it just moves softly up and down without the click. Could I have damaged something when I mis-wired?