The connector board for wirng motor broke in pcs when disconnecting wires. Im pretty sure what goes where still. But do I need the board? There is 1 wire that goes to board and nothing else.
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

I have a 120vdc treadmill motor that has a motor controller board and a transformer to operate it. My question is is there any way to rigg it up to a 12v deep cycle battery. I was thinking all i would need is some sort of step up transformer 9-1 if they make it or 10-1. I would aslo like to have speed control which i assume would work through lowering the voltage. It runs fine off the 12v batter just not near the rpms i need. I know it will drain the deep cycle very fast but im not worried about that.
      
motor #1 came back from servicing and was told it was shot (he said it  was grounded).  i have another motor #2 that im going to see if hell  mount (if it runs).  however motor #2 is designed for 230v.  what needs  to be done to wire this back up considering it is a 120v service.  (i  believe motor #2 was hooked up once before on this service so i know the  power is there)
      
My brother-in-law has a Coleman 8750 Watt portable generator with a 13hp Honda engine.  Worked fine for a couple of years and then all of a sudden it wouldn't provide any voltage at the outlets.  So he called up Coleman and they said the problem was probably a $50 control board.  So he ordered one and installed it.  This temporarily fixed the genset but after an hour or so the electric quit again.  So it appears something is causing the control boards to go bad.  Any idea what could be causing this?
      
i think our dishwashers control board is messed up. i think i heard i can test whether it is working with a multimeter or not. if so how can i? the cycles options a  pots/pans, normal wash, water miser, china gentle, and quick rinse. only the china gentle option works. the three other separate options a  high temp scrub, santi-rinse, and air dry. none of these work... also the delay hours options do not work either. and when i try to cancel or drain it, it will not stop unless u open it (but when u shut it, it starts until it finishes.) can all of this be fixed if i replace the control board? or do u think it will fix it if i change the fuses? or both? if not, what other problems could be causing this?
      
Hi, I have a 6" craftsmans metal cutting lathe and trying to wire a drum switch to it. The motor is a 1/3 hp westinghouse split phase motor 6.3 amp 1725 rpm. The switch is forward-off-reverse. There are two posts and two wires on the motor I'm not sure witch ones are start or run and how to go about wiring it there are 6 screws on the switch.I could probly post pics to someone  Thanks
      
I have a LEM .35hp meat grinder that did not come with reverse. It is a PITA to use and not have reverse. It is a 120v 250w motor, w 2 caps. There is no schematic on the cover, so I have no idea what which wire goes to where. I plan on using a DPDT switch to reverse it. on-off-(on or mom) switch. I have attached pictures of the motor wiring.  White/black come in then go into motor. White comes out of motor then to larger cap, other wire from large cap goes to red (into motor). Red comes out of motor into smaller cap, second wire to small cab is blue going into motor.



http://i1086.photobucket.com/albums/...n/IMAG0021.jpg

http://i1086.photobucket.com/albums/...n/IMAG0020.jpg

http://i1086.photobucket.com/albums/...n/IMAG0022.jpg

Any help would be appreciated.
      
I bought a replacement motor (Dayton 6k778k) for my attic fan.  I removed the old one and it has two wires coming out that connect to two wires that go down to the light switch that turns it on.  They were connected by those plastic twist things.  So, I open up my new motor assuming that there would be two wires coming out of it that I would just connect to the existing wires, however there are just a bunch of blade connectors and I have no idea what is supposed to connect to what and how.  I'm attaching three pictures. One is the old motor/wires, the second is the inside of the new motor, and the third is really the only thing that alludes to how this should he hitched up. 3 & 2 were pre-connected out of the box...which leaves 4 & 1.  Is one of the wires from the light switch supposed to connect to 4 and one to 1?  If so, which one goes to which? Do I need to put blade connectors on the end of the wires that go down to the light switch in order to connect them?  Any help is much appreciated.
      
hey i jus need a simple answer.  single phase pump motor needs to be connect to power.  there is one green, one black and one red/white? (i believe this wire used to be red but faded).  i kno green is ground, i just need to know which wire gets hooked up to L1 and L2.  the motor is set on 115V.  and dont worry power is cut off completely.
      
I am wiring a three phase motor through a two pole vacuum switch. two lines go through the switch but one line is always hot to the motor. is this proper or is this a safety issue?
      