Sudden Loss Of Power At One Outlet..?

Well it's not really an outlet but just a junction box that has black, white and bare copper coming out.  I was told by someone before that this would be the end of the line for this circuit since the wires don't go any further from this box.   Its located in my attic just below the eve opening for an attic fan.  I checked the black and white wires a few years ago and measured 115 vac so I installed the attic fan and it was fine until this year.  No fan operation so I check for power and I'm measuring about 3 vac across the white and black wires now.  I disconnected the attic fan and measured the same 3 vac.  Test fan on another power sourch and it works.  Everything else on the circuit seems to be working.  Any ideas what might be happening here.  The attic fan really helps a lot and I'd like to get it working again.  If I need to provide more information please ask and I'll do my best.  Thanks for any help.
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

I have an outdoor light fixture that I am trying to replace.  The house was built ten years ago.



When I removed the original lamp, I noticed one of the two leads was wired to the ground, and one was wired to the black wire, which is hot per my current sensor.  There are three wires in the box - black, ground (bare copper), and white or neutral, all from a single romex cable.  Unfortunately, I do not recall where the white was when I removed the original. 



I wired the new lamp per the instructions, something I have done many times before - black to black, white to white, and bare copper ground to ground.  Nothing.  The lamp and bulbs are brand new, and I have tried four separate bulbs.  I checked the black and neutral with my current sensor and with the switch on and the lamp installed this way, both show as hot. With the lamp not installed, the switch on, and the wires disconnected only the black shows as hot.  The switch is single pole, and appears to be wired correctly with a black to each screw on one side and a copper ground on the other.



Assuming the new fixture was bad, I reinstalled the old fixture correctly -  black to black, white to white, and bare copper ground to ground.  Still nothing. No light, and I confirmed the bulb is good by putting it in another lamp.   The only way to get it to light is to connect the neutral in the lamp to the bare copper ground.



I capped the wires, turned the circuit back on, and identified all the outlets, switches and fixtures on the same circuit.  I opened every one of them up (four lights and eight outlets) and found three (one switch and two fixtures in another room) where multiple commons connect.  All were properly connected.  My outlet tester shows all outlets as "correct".  I found no instances of grounds connected to commons or vice-versa.



Any ideas?  Is it proper to wire this thing the way I found it?



Thanks for any and all advice!
      
Hi, I recently moved into a 1954 house with a  20amp electrical system, not the old fuse type, but there are no ground wires.



I removed an old light and replaced it with a light fan combo. As I removed the old light (after turning off the breaker) I noticed from the ceiling that there were 2 white wires tied together with a wire nut and 2 black wires, one attached to the white wire in the light and the other attached to the black one from the light. Feeling this was wrong and should be black to black, white to white, (even knowing full well the light was working fine before I disconnected it) I wired the fan the way I've always wired fan lights,  white to white, blue and black to black.  (again, knowing full well the light was working the other way). Turned breaker on then powered on switch. POP at the switch, breaker switched off. I reworked it back to the way it was before with whites tied off, black to white, black and blue to black, turned it back on and  viola, things worked fine. (I know, duh... Right???)

2 questions from this experience...

1. Why would the 2 whites be tied off with only black wires used?

And 2. It seems that one of the light switches in the same circuit as the blown one is now working soft. In other words, it used to make the normal click noise when turned on/off but now it just moves softly up and down without the click. Could I have damaged something when I mis-wired?
      
I have two 3-way switches in my master bath that have never worked properly. The house is very old and has been worked on over the years by many different people with greatly varying levels of skill. I was finally fed up with these switches and tried to fix them. I tried to follow instructions I found online, so with the power off I disconnected all the wires from both switches, then turned the power back on and used my volt-meter to discover which wire was hot. It turned out to the a red wire at switch #1. The other two wires are white and black (and yes, there also is a ground). I connected this hot wire to the darkest screw, connected the white and black to the other two screws and tried to test for continuity at the other switch. I couldn't get a reading on any of the wires at the other end. I tried turning the power back on and testing to see which wire was now hot at the second switch. It was the white wire, so I attached that to the darkest terminal, and attached the red and black to the other two terminals. The switches don't work any better than they did before I started - that is, both switches have to be turned on for the light to come on. What is my problem here? Thank you!
      
Hey everyone - question about home wiring that was done when the house  was built about 20 years ago (which putting it delicately...is very  shoddy at best).  I'd like to think of myself as fairly knowledgeable in  basic home wiring...but this one has me baffled and I really hope  someone can help.



I am redoing a screened-in porch at the back of our house.  There is  currently a working outlet, and single-pole switch that turns on an  outside bug zapper, and a wire running coming into a second  switch...then leading into nothing in the ceiling (presumably for a  future ceiling fan / light install that was never completed).  I gutted  the entire porch and using one of those audible voltage testers,  discovered the wire than ran into the second switch / ceiling box did  NOT work. 



Not thinking much about it, I tried figuring out how the first switch  (to that outdoor bug zapper) was wired.  Most of the wiring for that  switch and the outlet I mentioned is behind the plywood sheathing of the  house...so it's near impossible to figure out where it goes.  Initially  it LOOKED like the power from the circuit panel came into the outlet  first...and then went out to the bug zapper switch.  (Why did I think  this?  The outlet had a B/W wire coming into it...and another B/W going  out back into the wall somewhere.  Tracing that wire along the basement  foundation best I could...it looked like it went right into the bug  zapper switch).  So wanting to completely eliminate the bug zapper  switch, I disconnected all of the wires that were connected to the  outlet to figure out which set was leading to it.



Here's where I got confused.  When I did this and re-tested voltage at  the outlet, one set of wires was live...and the other set was dead.  And  that makes perfect sense.  Yet the bug zapper switch STILL worked.  OK -  so my conclusion: the power for this bug zapper switch isn't coming  from the outlet.  No problem.  But just because I was near it, I decided  to also check that 2nd switch / ceiling wire combo...and what do you know - it was LIVE!



I got super excited it was working but then super baffled because I  didn't do anything to that ceiling wire at all.  In fact - all I did was  DISconnect 2 sets of wires at a nearby outlet. 



Confused but happy, I was ready to pack it in for the evening and  re-connected the incoming / outgoing wires back to the power outlet.   Flipped the circuit breaker on.  No issues.  BUT - now all of a sudden  the 2nd switch / ceiling wire that magically started working was NO  longer working - just like it hadn't been since I started this whole  process. 



Logic is telling me it's obviously got something to do with the outlet  wiring...since that's the only thing I messed with.  But why would the  ceiling wire all of a sudden become LIVE when the wires going into the  outlet were all disconnected?  It's certainly a first for me.  Can anyone help me figure this mystery out?  Thanks gang!
      
I am trying to install a SunSmart Digital Timer to my hall lightswitch (single pole). The timer has 5 wires: Black, White, Blue, Red, and Green. My switch box only has 3 wires: Black, White, and the bare ground wire. I connected the black to the black, white to white, and green to the bare ground. I have power to the timer but the light doesn't work. What should I do with the blue and red wires? Right now I have each capped off. Thanks.
      
I was in my attic today doing some work when I noticed a bare twisted copper wire that ran along a ceiling joist.  All along it was charred wood and charred  fiberglass insulation.  Luckily the fire it caused did not sustain itself and I was able to find the problem.  I then traced the wire and figured it originated in my breaker box (although I could not determine exactly where in the box).  It then ran across my attic alongside a ceiling joist and down into a wall ending up connecting to my water meter.

  Several months ago,  the electric company was restoring power to my area and ended up sending a power surge into my house taking out an oscillating fan, a toaster and a GFI outlet.  Last winter, I also had to have my electric meter pole replaced by an electrician after a tree branch took it out during an ice storm.

  I was wondering if one of these events could have caused the ground wire to heat up or something else entirely is going on?  I am suppose to have a company blow in  insulation soon and I need to figure this problem out.  Any help would be appreciated.  Thanks.
      
Hello everybody! First things first..I don't know much about wiring besides there being a positive, negative and a ground.



I am in the process of gathering information about installing two lights on the soffit of the corners of my house. There is an outside light by the sliding glass door that I was going to tap into for power, since the switch for it is in the kitchen.



My question is will this be possible if I was to run two twin head flood lights off of the same switch.   (  http://www.lampsplus.com/products/br...ht__h9572.html   )





What would be the easiest way to run the wiring for this? Through the soffit or just through the attic? The problem with the attic is there is vaulted ceilings in a few rooms of my house so it is pretty much impossible to walk in the attic to the far side of my house...actually I don't even think it is possible with the amount of insulation and how the ceilings are.



How would I go about mounting the light to the soffit? A junction box? Will I have to run conduit?



Here is a picture of what I am trying to do. Excuse my art skills in paint.





Thank you!
      
Going through a crazy heat wave here in SoCal, and one of my tenants called to tell me that the electricity isn't on in some of his rooms. He turned on his portable AC unit that he has been using all summer and something may have happened.



Downstairs:The dining room light switch, downstairs light switch do not work. All outlets around them do work though, which is odd cause I would have thought they'd be on the same circuit.



Upstairs: The side bathroom light switch does not work, but outlets all work. In the master bedroom (where the AC unit is located), the master bathroom light switch does not work, nor does the master bedroom light switch. All of the outlets do not work either. I used my outlet tester and it gave me the hot/ground reversed lights. I think this means that the white/black wires are reversed on the outlets (has not changed recently).



I went over, checked all of the breakers. Switched them to off, then back on, did not fix the issue. All breakers stay in the on position without tripping, so no shorts?



Checked all GFCI's, hit test, then reset, did not solve the problem.



We unplugged everything from all outlets, and retried, but it didn't work.



I checked continuity between the main power lines, and the output of the circuit breakers, and all were fine. I did NOT check the voltages though, and will do so in the morning when I stop by again.



Is there anything else I should check?
      
I am only using a simple "non-contact" voltage detector. I am getting a reading from the switch, along part of the line and then at the lights themselves, but the lights are not coming on. I have not gotten into the attic yet to check the line and junction box. What could cause this? An open connection or loose connection? Any help with troubleshooting would be great.



This is a new install of lights, they were not existing. Power is at the switch. Had single pole now I have a double switch. (the existing light that was on the single pole is still working fine). At one  point I connected just the new lights to the existing power, single pole switch, and still did not have lights.
      
I bought a replacement motor (Dayton 6k778k) for my attic fan.  I removed the old one and it has two wires coming out that connect to two wires that go down to the light switch that turns it on.  They were connected by those plastic twist things.  So, I open up my new motor assuming that there would be two wires coming out of it that I would just connect to the existing wires, however there are just a bunch of blade connectors and I have no idea what is supposed to connect to what and how.  I'm attaching three pictures. One is the old motor/wires, the second is the inside of the new motor, and the third is really the only thing that alludes to how this should he hitched up. 3 & 2 were pre-connected out of the box...which leaves 4 & 1.  Is one of the wires from the light switch supposed to connect to 4 and one to 1?  If so, which one goes to which? Do I need to put blade connectors on the end of the wires that go down to the light switch in order to connect them?  Any help is much appreciated.