Electrical Run To New Pool House

We are in the process of redoing the area around our pool. As part of this we are adding a pool house and hot tub (separate from pool).



I have a couple Elecrtical Contractors coming out this weekend to price/put together a plan. Along with talking to several indivuals, I've been lurking around reading and trying to gather info but feel the need to have as much info available prior to getting these estimates and plans. Please excuse any incorrect verbage i might use and appreciate any corrections to my terminoligy



So this is what i have 



The pool house is approx 100 ft from the house.

It will have a few and outlets for blenders, minifridge, tv etc

the pool equipement consites of a pump, heater and a sand filter. The pump and current heater run off standard 110 lines (however if i upgrade this I dont know if the new one will require a 220 line



The pool light seems to run off a standard line as well



The hottub requires a 220 40amp line



There will be landscaping lighting as well as 2 more outlets for accesories



The original setup prior to last year had what looks like 6 or 8 guage (3 wire) directly buried about 6-8 inches under  ground. it was running what look to be two 20amp circuits from the main panel inside the house. This wire got split to two separate outlets near the pool. One went directly to the pool equipment and on directy to the pool light switch and some landscaping ighting.



With all the enhancements we are making i'm wondering what the best approach will be.



I assume a sub panel in the pool house that has one "main breaker" and has its own ground. Then one run to the pool equipment and one run to the hottub and a couple runs to the accesories i mentioned.



I have seen several replies on here where individuals talk about  "if they were doing the job this is how they would do it". Id be interested in some responses



What type of wire would be best to get it to the pool house

Does it run right from the main panel in the house?

Does direct burial make sense or shold i put it in conduit? I'm already digging a trench three feet deep for water and RG6 (which will be pushed thru conduit)



Any question i should make sure i ask the contractors?





Thanks in advance for any input
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

Live in California...  Pool and backyard remodel



Running a new 100Amp line from the main electrical house box that is 200amp to the new Hayward ProLogic Pool sub panel for the pool equipment. Is that #2 wire or #4?



The pool installers are telling me that they need 50 amps for the 3 pumps, 2 pool lights and gas heater that I have. 



The reason that I'm running 100amps to the sub panel and only using 50amps for the pool is because there is electrical going to the overhang and backyard that can be controlled by a remote that talks to the ProLogic sub panel.



I have a overhang/BBQ area that has 17Amps for the refer and BBQ, a water feature which is about 15-20 amps, 2 ceiling fans for the overhang, low-voltage lights for the overhang, low-voltage landscaping lights for the backyard only. I think that is about it.



Inspector is telling me that I need a GFCI at the sub panel. Is this a 100amp GFCI prior to the sub panel being wired? Or does each piece of equipment need a GFCI?



I am having a licensed electrical contractor do this, but I'm just trying to do my homework because some of them are not knowledgeable about pool wiring... 

(BTW, I had a licensed contractor out yesterday, to give me a bid and he said that they didn't make a 100amp GFCI, which of course I did see on the internet, not using him!!)
      
First off im in So Cal. and a few months back my pool equipment stoped working after a rain storm. I have an underground conection that is accseible through a plastic box in the concrete. There is a water proof box there that housed the wiring as it runs from 220 breaker underground to the pool equip., I opened it to find it full of water. The short burned the wiring some where under some 60 feet of cement. I forgot to mention the wiring in existing conduit will not pull through have tried several times even as despreate as a come-along.



Ive had an electrician and Genral contractor both look at it and both said wiring is fried, but im looking for advice on my two options.



1st is cutting a trench in the cement about 60 to 70 feet from circuit breaker to pool equipment. Then using conduit the whole lenght like it was previously but no under ground box. Just two connections breacker & pool Equip.



2nd option the breaker is near my atic. run power from breaker through the house atic to where pops out on the other side of the house. would be about 50 feet through atic and about another 50 feet of conduit 25 above ground attached to eves and 25 below ground to pool equipment. This is a similar route as the gas line to pool equipment they will come out of atic about 20 feet apart then eventually follow similar path is this a problem?? I was told to use 12-3 Romex?? Suggestions on which route to take would be great. Atic is clearly easyer but concerend with closeness to gas line. Thanks before hand for the help
      
I am having my inground pool renovated. The pool is made from aluminum panels. They will be replacing about 5 panels with steel and the contractor said they need to be grounded. Now I have checked the rest of the panels and there is no evidence of any grounding that I can see. The only thing I have found is at the end of the pool they will be repairing there was some wire connected to the top railing and buried into the dirt.

I have worked with electrical contractors when I was younger and do electrical work at the power plant I work at.

How would I ground these walls and what materials do I need.
      
Hello, we recently purchased an above ground pool and had it installed.  The city building inspector came out to inspect the electrical and said we would need a bonding grid around the pool and bonding plate in the trench.  When I questioned how to do this, his response was to contact the pool manufacturer.  I have done this and the manufacturer tells me that since my pool is aluminum wall and the rest of it is resin, I do not need the grid and plate, but will need to insert a bonding screw to the skimmer  and drop a copper wire from the screw into the ground.  I asked for a schematic on how to do this, but they could not help.  I am also concerned that they told me something different then the building inspector did.  Can anyone help me with this please?  Right now I regret getting this pool, hoping someone can walk me off the ledge.  Thank you so much for you time.
      
Our pool was installed 10 years ago and we need to change the 3 underwater lights because they are leaking. The cable for each light box goes through a conduit and up to a "deck Box" or junction box per code so water from pool can't run up to the box. In order to change the lights we need to locate the box and pull the wires out, then feed the wires through for the new light. The problem is that one of the boxes seems to be missing. That light sits under a stone waterfall and there is a planting area behind the waterfall. Ive searched under all the bushes and even done a bit of digging but cant find the box. I'm wondering if there is some smarter way to locate it.



I tried a metal detector but there were too many false alarms from every metal scrap the work men left behind. I was wondering if there is something that could be fed through the conduit to junction box that would send a signal allowing it to be located. I know the cesspool guys use something like that and thought maybe an electrician might have a similar tool.



The new lights are completely different than the old ones so we can't just change out one. if we can;t change this light we can;t change any of them and the whole project goes down the drain. Any suggestion would be greatly appreciated.
      
Hi guys. I'm Dan, and I'm in Knoxville, TN. I know running power to a shed is a very common topic here. I've been doing tons of reading and feel pretty comfortable with the requirements, but I have two questions I haven't been able to find a clear answer to.



First, my situation: I'm having a 10x16 shed built in my backyard, to be used primarily as a woodshop. I need more than a single circuit, so I know I need a subpanel and two grounding rods at least 6' apart, bonded to the subpanel with #6 bare copper wire.



My house has 200 amp service, and the main panel is in the garage at the opposite corner of the house from where the shed will go, so it would be pretty inconvenient to run a feeder from, there. But there's an existing 100 amp subpanel in the basement, presumably installed when the previous owner finished the basement. I'll be running a 60 amp feeder from that subpanel to the shed.



My total run will be something like 75', so I'm running #6 THWN for the two hots and neutral, and #10 THWN for the ground. I plan to bury it in 1.25" schedule 40 PVC, buried 18" deep.



My first question relates to how I need to run the wire when it's not underground. The basement is finished with a drop ceiling, so I plan to run the feeder across the drop ceiling, out of the house, down to the ground (it's a walk-out basement), then underground the 26' to the shed. I assume it still needs to be in conduit for at least the part that runs up the wall of the house. But what about inside, when it runs through the drop ceiling to the panel? Does it need to be in conduit for the whole run? Or would I just staple the four wires to the joists or something?



The other question relates to the trench. I've got a rain gutter downspout that discharges right at where the shed will soon be, so I'm running a 40' length of 4" PVC to pipe that water past the shed. It will be buried just about 6-12", just enough to run under the shed. Can I run the power conduit in the same trench (obviously, deeper)? Presumably I'd dig the 18" trench to the shed, lay the schedule 40, then add a few inches of dirt to bring it up to about 12" deep, and extend the trench past the shed at that depth, then lay the 4" drain pipe and backfill. Or do I need to dig two separate trenches? Is there a rule about how far apart they need to be if so?



If anyone sees any other flaws or concerns with my plan, please do speak up, I want to do this right. Thanks!



Dan
      
I had a previous thread about bonding my inground pool. I had it done yesterday. I set up all the plumbing for my filter and I am going to wire it up tomorrow.

This pump was wired up once before and it is being moved. All the wiring was removed when the contractors were breaking up the concrete. It has a 25 amp breaker that I am going to replace with a GFI 25 amp breaker. I am going to wire it from the breaker box to a switch (1 foot from the box) to the receptacle about 45 feet away. I am going to use 12 gauge solid wire. I am not sure which would be better. Should I use 12/3 romex and use one as the ground or use 3 separate wires colored white, black and green. Also they had the green wire going to the ground bar in the breaker box. I guess I will attach the green(ground) wire to the ground bar and then run it to the green lugs on each receptacle.  Also which types of boxes would be best to use metal or plastic. I am going to be using plastic pipe to run the wires.
      
Hi guys,



I have a Torx 7200 and, while the main wheel turn and the switch "clicks" each time the pins hit, the power doesn't toggle on or off. Is this an easy (cheap) fix or do I need to buy a new timer? By the way, it is controls my pool pump.



Thanks
      
i am going to run 3/4 pvc in 2 foot trench to the 6x6 i have burried i want to hook up a twist lock outlet and a switch to also shut it off. along with a 140amp single pole timer how would i wire this

Thanks

Bill
      
can this be ground to the same copper pipe that has a ground from the service panel    since that  pipe is right there already supplying the tub . 



thanks for the answers so far.



i meant whirlpool .