Wiring A Ceiling Light/fan

How to install a ceiling fan light when the power 14/2 goes to the fan/light then to the fan/light control (blue, black, black/white, green)?
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

Hello -



I'm attempting to install a new bathroom vent fan / light combo.  I pulled out the old one from the ceiling and am ready to install the new one.  I'm not sure how to wire up the new one.



The wire coming from the 2 Switches/Wall has the following 4 wires:  Black, White, Red, Bare Copper Ground



The wires coming from the Light/Fan Unit a

Light:  Black, White, Red

Fan:  Black, White

Fan/Light Housing:  Green Ground Wire



Any help would be appreciated.



Thanks!
      
I am trying to install a SunSmart Digital Timer to my hall lightswitch (single pole). The timer has 5 wires: Black, White, Blue, Red, and Green. My switch box only has 3 wires: Black, White, and the bare ground wire. I connected the black to the black, white to white, and green to the bare ground. I have power to the timer but the light doesn't work. What should I do with the blue and red wires? Right now I have each capped off. Thanks.
      
Hi, I recently moved into a 1954 house with a  20amp electrical system, not the old fuse type, but there are no ground wires.



I removed an old light and replaced it with a light fan combo. As I removed the old light (after turning off the breaker) I noticed from the ceiling that there were 2 white wires tied together with a wire nut and 2 black wires, one attached to the white wire in the light and the other attached to the black one from the light. Feeling this was wrong and should be black to black, white to white, (even knowing full well the light was working fine before I disconnected it) I wired the fan the way I've always wired fan lights,  white to white, blue and black to black.  (again, knowing full well the light was working the other way). Turned breaker on then powered on switch. POP at the switch, breaker switched off. I reworked it back to the way it was before with whites tied off, black to white, black and blue to black, turned it back on and  viola, things worked fine. (I know, duh... Right???)

2 questions from this experience...

1. Why would the 2 whites be tied off with only black wires used?

And 2. It seems that one of the light switches in the same circuit as the blown one is now working soft. In other words, it used to make the normal click noise when turned on/off but now it just moves softly up and down without the click. Could I have damaged something when I mis-wired?
      
I raised a shed and disconnected the wiring from the main building to the shed. Now it's a month later and it's time to hook the power back up. From the main building I have power into the shed with a white, black, red and copper wire. Originally the power went into the outside light fixture and then off of that it went to another light and two outlets. The original confiruation allowed of us to turn the shed's outside light on and off, from a switch inside the main building. With the power off to the light, we still had power to the outlets and internal light. The outside light fixture has black and white wires. The wire to the internal light and the outlets has a black, white, and copper wire. So how do I wire this so that the main building switch can control the outside light on the shed, while still having power to the internal light and outlets, regardless of the switch being on or off? (I wired the internal blacks and whites all together, which just ended up with the outside light always being on.)
      
I replaced a ceiling light with a fan/light with a remote. everthing works. their is one light switch and one dimmer switch. The dimmer switch has a red wire and a black wire connected to the black wires coming out of the dimmer switch, plus a green wire hooked to the metal portion of the dimmer. My question is: Do I have to remove the dimmer switch, if so, can I disconnect the red and black and hook them together? If I have to replace the dimmer with a regular switch, what kind of switch do I get?

Thank you
      
Hi, I have a fluorescent light I'd like to remove and add a tracklight.



Luckily it's in the basement with an unfinished ceiling.



here's the circuit map as is now:



1. breaker to fluorescent light.... connections inside

2. fluorescent light to switch at the top of the stairs

3. switch to the light in the stairwell. This terminates the circuit.



The wiring is all 14/2



I'd like to replace the the fluorescent light with a track light, but I'm not sure how to continue the circuit to the switch in the stairwell.



Is it safe to...



1. bring the cable from the breaker to the junction box.

2. connect the black wire with the black wire on the light AND the black wire leaving the box to the switch in the stairwell using a marette.

3. connect the white wire with the white wire on the light AND the white wire leaving the box to the switch in the stairwell using a marette

4. connecting a 6 inch bare 14 gauge wire to the box ground screw, then using a marette, connecting it with the ground wire from the cable entering the box as well as the one leaving and also the ground wire from the light.



Will this work and is it safe?
      
Hi,



I would like to wire a switch to be able to cut the power to the ceiling mounted outlets that feed our garage door openers. Running new wiring to them will be a bit cumbersome, so I am hoping to avoid that. The ceiling outlets are powered by light fixtures in the garage (one near by each outlet). There is a 3 wire romex cable running from the light switch to the first light and another one between the lights, and then regular 2 wire romex cables from the light fixtures to the outlets. The red wires in the 3 wire cables to the lights are switchable, the black wires are always hot.



I mainly want to be able to cut the power to the doors when we are away on vacation, and the reason for that is that one night both doors somehow opened up - I have no idea why. I'd hate for that to happen when we're away. Unplugging and plugging in the openers is a bit of a hassle due to the high ceiling.



I thought about wiring in a switched outlet so that I could just reach up with a long handle of some sort and switch off the power to the outlet. It would not be ideal, but definitely easier than getting the ladder out and unplugging the door openers.  However, there is possibly another option that I'd like some input on if anyone cares to comment. I believe I could wire in a switch on the wall next to the light switch that would allow me to cut the power to the black wires in the 3 wire cables. This would cut the power to the ceiling outlets and anything downstream from there (possibly an outside light, I would need to check on that).



My question is, are there any potential issues with this sort of wiring? Is there perhaps any code violation if both hot wires in a 3 wire cable can be switched off separately?



Thoughts?
      
Hello I need seriouse help! In my situation I have a three switch, one for the light, one for the vent fan, and one for the heater. This is in a bathroom rent house. My problem is that when I turn the switch on for the light, the light and fan turn on, when I switch the heater on, that switch does nothing, the same when I switch the fan on. The wall plate is labeled: light, fan, heater. So what I attempted to do is put a switch outlet combo in. I have two black wires, two white wires and a ground. So I put the black wires on brass and the white wires on black,( they are black screws instead of silver, not sure if I got the right kind of switch). So when I did that, when I turn the switch on, the fan turns on, but no light, also when the switch is on the outlet is hot.( which fine that is how I want it). But what did I do wrong, why does fan work but not the light. I my biggest fear is that I might have made a fire hazard. Please help and tell me if what have done is safe, and maybe help me figure out how to turn the fan and light on with the same switch..  Thank you for all your input, have trouble falling asleep, keep thinking the house might burn down.. Sorry for the long post
      
Hello. I'm a new home owner and DIY-er. I have 3 fluorescent lights  in my basement. I just replaced the fixtures' older ballasts with new  T8 ballasts in the first two lights and they work fine. I am having  trouble with the third light's wiring to the ceiling. I cut and removed  the old ballast without paying much attention because I was able to wire  the first two lights without any problem. I connected the new ballast  to the bulb sockets in the fixture, just like I did with the first two  lights. When I went to connect the ballast's black and white power lines  to the ceiling lines, I was thrown off by a red wire, which I guess is  connected to the light switch.  In addition, this light is connected to  the one of the other fluorescent lights and both are controlled by the  switch. I have attached  pictures of how I have it wired.



The way I have it wired now,  the other light turns on and works fine when the switch is flipped.  However, this light has the bulb flicker and then not turn on. If anyone  can tell what I'm doing wrong from looking at the pictures, I'd  appreciate any help! Thanks!
      
Hello all, and thank you in advance for any help you can provide! Here is the deal I wanted to put a bathroom exhaust fan in and was told I could come off the existing switch to cut the wire, install a junction box, tie the wires all back in adding the wires for the fan. Trouble is the bathroom light stays on with the switch off. Turn the switch on light dims and the fan now runs, switch off fan shuts off light goes bright used black to black white to white where oh where did I go wrong!?