2 Baseboard Heaters/no Junction Box

I have a 20 amp circuit running into my addition that I planned on running one baseboard heater from so I don't have a junction box. Now I'm putting one in the bedroom and one in the ensuite. I'm OK with using the thermostat on the heater instead of the wall so I'm wondering how to run the circuit from one baseboard heater to the next using one circuit and separate thermostats. They are back to back separated by a wall and I haven't closed in one side of the wall yet.
      


Similar Tutorials

How to Lay Sod - The Right Way!
   - Make sure the green side faces up! And, there are a few more steps if you want to ensure a nice looking lawn. Prepa ...
The Difference Between Volts, Amps, and Watts
   - This article explains the difference between Volts, Amps, and Watts in an easy-to-understand non-scientific way. T ...
Water is Leaking from the Toilet – What do I do? (How to replace the wax seal for a toilet.)
   - If there is water leaking from the toilet, you need to make sure that you know from where the water is leaking. Che ...


Similar Topics From Forums

I have a 15 amp breaker that services one light, one GFCI, one bathroom fan, one blade fan and one smoke detector. Can I also add one 750w baseboard heater using 14/2 wire?
      
Hi,



Forgive me if this has been covered elsewhere - a cursory check didn't

bring up an answer, but maybe I didn't search on the right thing...



I've got to replace a baseboard heater that was located under a receptacle.



I was first thinking this is covered by the "grandfather" clause, but a bit more checking has me confused - it looks like maybe the NEC doesn't specifically prohibit this (maybe they do in the newest code book), but pretty much all manufacturers now seem to specifically say not to do this, so it would seem to be prohibited.



So what do you do?  Here's a couple of pics of where I have to put this unit:



http://www.rkgphotos.com/recent_stuf...er_corner2.jpg

http://www.rkgphotos.com/recent_stuf...er_corner1.jpg



a 1500W unit is what should go here.  just pulling the receptacle/putting on a cover plate means there's gonna be more than 12 feet between receptacles along this wall.



Its also complicated by this being both an outside wall and a common element so I didn't want to butcher it up completely.



It seemed like I could: 1) use 2 heaters with a gap under the receptacle (though the spacing kind of sucks for this), 2)pull the receptacle, put on a cover plate and forget about it (practically not a problem but violates the 12 foot rule), 3) use the receptacle box as a J box and run a line down to where the heater is and use one of those funky receptacles you mount to one end of the heater, or 4)??



Anyway, suggestions/observations would be greatly appreciated.



Thanks,

rkg

(Richard George)
      
We are just beginning to start with our kitchen remodel. Today, I mapped out all the circuits and this is what I found.



Circuit # 7 - 20 amp circuit to 1 back splash outlet then to 3 kitchen wall outlets, then to a closet outlet and closet ceiling light and then to a side  porch light!



Circuit # 8 - 20 amp to Dishwasher and Disposal



Circuit # 9 - 20 amp circuit to microwave and kitchen ceiling lights. 2 patio recessed lights and dining room ceiling light.



Circuit # 12 - 20 amp circuit to another back splash outlet then to 2 dining room wall outlets.



Circuit # 14 - 20 amp to Refrigerator only



Circuit # 18 - 15 amp to GFCI outlet in garage then that feeds 3 outlets for 3 bathroom outlets and 1 outside patio outlet.



I going to have to add 1 more back splash outlet due to increase in counter space. I'll put the microwave on a dedicated circuit. So I need 2 additional breakers but I only have 1 blank spot in the breaker panel. I guess I can add one of those slim tandem breakers.



So my question, is it ok to have additional wall outlets on the same circuit as a back splash outlet?  If it's ok I'll lighten up circuit # 7 by putting some of those wall outlets on the additional back splash outlet.

Oh, I have 2 20 amp circuits I did not get identified yet! I'll get to those tomorrow.



thanks!
      
remodeling basement ..don't want to tape into my furnace for heat ... have one large room 480' sq. and am thinking of using two or three  baseboard electric heaters [possibly Cadet                                                              6 Ft. 1500 Watt 240 Volt Electric] as heat source on outside walls ..out side walls insulated and basement not real cold ...I'm doing electrical now ..do these need to have there own independent run or can they be wired to 3 basement pull chain lights which I seldom use and are on a 15 amp circuit .........the basement remodel has 3 separate runs [ 2 lights 1 outlets ] ..thanks for any advise
      
Hi All,



Planning on installing a Zip contract 2 point of use overhead water heater, 10 litre 2kw.



Query can I use current mcb & rcb installed in distribution box which was used for 3kw immersion water heater.



If not can I use a 45amp 30ma mcb and if so what rcb rating should I also use.



I am assumming that the old water immersion circuit would be ok or would the rating be too strong being it 3kw as opposed to the now 2kw.



Cheers,

Nutrifix.
      
I want to run a new 12/3 to wire a room added on the back of the house. One circuit will be 6 wall outlets. The other will be a ceiling fan and 4 recessed cans. Can I add 2 outdoor lights-using standard outdoor bulbs-to the same circuit as the ceiling lights? Do I use the wall switch(box properly sized) as the junction for the outlet wiring and feed to wall switch for outdoor lights?
      
This is kind of a complicated question, but I  think I have figured out how to do it right.  I wanted to run it by some folks here before going to the city code enforcer.  See the attached diagrams for details.



I  am planning a fairly elaborate lighting scheme for my home theater  area, mostly because I plan for the theater automation to be a hobby for  me. (I'm an electrical engineer)

 

I want to have banks of lights that I could later choose to group  differently onto dimmer switches.  For example, I have six can lights.   Some people I have talked to think I should dim the front four together  and back two separately.  Some think I should dim the front two together  and back four separately.  Some say I should dim them all together. 



So I decided I'd run each group of two cans to a junction box, run  the switches to a junction box, and then wire the switches to the lights  in the junction box - then I could later change it if I decided it should work  differently.  In addition, this would keep the junction boxes the  dimmers were in free from extra wires, since I plan to buy nice dimmers  that are fairly deep and would take more space in the switch boxes.  And  if I find that using switches differently would make it more intuitive,  I can change which switch controls which lights easily after the fact.   This would also allow me later to possibly control the lights with an  automated system.

 

There are some track lights and rope lights, as well as a couple  receptacles that would all come back to the junction box where they'd be  connected to the switches/dimmers.



I am bringing in power from  two circuits to balance the lighting.  I plan to put some of the lights  on one circuit and some on the other.  The second circuit has some other  stuff on it already, so it has less load left over, so most stuff will  go on the first circuit.

 

Also to save on wiring and make running wire easier, I was planning  to use 14/3 wiring where possible.  Any given 14/3 wire would  always be connected to only one of the circuits (no shared neutrals).



The attached files show my exact plan for each circuit. Note they both  share the junction box in the upper right corner of the pictures, they  also share the switch banks.  This allows me to decide which switches  control which lights, as well as decide which lights will be powered on  which circuit to balance them properly.  Note that the track lights are  each 2 circuit track, that's why I'm running 14/3 to each.

   

See the attached files for circuit #1 and circuit #2



I am running 14/3 NM to the switches.  I was planning to have two  switches share one 14/3 cable.  I am also running 14/3 to each group of  two light groups that I want to control separately.



I've also attached a diagram from the perspective of the junction box.



I also attached an example circuit on how I plan to use the 14/3 wire.

   

Here are some other decisions I made:



- The junction box will  be PVC 8x8x4 (256 cu. in.)  All the wires coming into the box add up to  70 cu in. so the box should be plenty large.

- All the grounds from both circuits will be tied together

  - The neutrals for both circuits will always be kept completely separate (NO shared neutrals)

- No 14/3 wire will ever carry power from more than one circuit (this would violate the shared neutrals anyway)



Even  though this is kind of elaborate and for hobby, I want to be sure to do  it safely and up to code.  Does anyone see anything wrong with  my plan?

 

Thanks,



Daniel
      
I have a tankless hot water heater with the following requirements:

Voltage/Freq:240v/60

Wattage:21kw

Max amp load: 88

Min req circuit breaker: 2x60

Min wire size: 2x8 AWG copper (note:should be 2x6)



Amps to house is 200. Breaker box is 10 years old with space to add new breaker. The old 30 breaker will come out, new 2x60 in, and new wiring will need to be run approx 15 feet to location of old water heater.



Initial quotes from electricians via phone are all over the place and I have someone coming to house on Friday for a site estimate. In my understanding, the work is straight forward as stated above. What am I missing? Or what might the electricians be thinking I am not (besides pulling a $40 permit)?
      
I have 200 amp service with a 50 amp service tap to the garage and another 50 amp tap to a small service panel for extra circuits. I have a 70 amp draw for a tankless water heater, 30 amp draw for the air conditioner, a 40 amp draw for the cooktop and a 40 amp draw for a double oven. I want to add another tankless water heater about 50 feet from the 200 amp panel. The new water heater requires three 50 amp breakers. How do I get the necessary service to the new water heater?
      
I've been the owner of a 1930s era Colonial Revival that our first major project is to rewire the house. We have a 100A main box that is maxed out, a combination of cloth 2-wire, flex, and some cracking Romex along with some downright dangerous open wiring in the basement, tapped wiring in the kitchen and study, some gangboxes that were wallpapered over in the bedrooms that we assume were wall lights (we have similar wall lights in the bathrooms), inadequate outlets in most rooms, no GFI. Etc. Etc. In addition the bathrooms are small and lack wall switches or outlets (they have two pull-cord wall lamps, with one lamp with a outlet.



Here is a floor plan with electrical represented on the ground and second floor. Still working on mapping the basement and the attic (which has a 3/4 converted finished "bonus" room.



My Father-In-Law who is a licensed electrician has promised to gracefully donate a couple months of his time to rewire everything. Also a bonus in this is the majority of outlets are mounted on the baseboard trim and not in the plaster.



My plans are to go with a single 200A main, likely double the amount of outlets in each room, GFI where needed.



While I know some basics, I want to familiarize myself a bit more on what is the best approach to rewire. For instance should I look at running conduit in just one spot of the house, or should I run two on each end of the house? I plan to do some major remodeling of some rooms in the future, especially the kitchen and bath so what are the best ways to ensure I have an easier time with these remodels?